Guest

Tools & Resources

SNMP Object Navigator


CISCO-RTP-METRICS-MIB

View compiling dependencies for other MIBS by clearing the page and selecting another MIB.

Compile the MIB

Before you can compile CISCO-RTP-METRICS-MIB , you need to compile the MIBs listed below in the order listed.

Download all of these MIBs (Warning: does not include non-Cisco MIBs) or view details about each MIB below.

If you are using Internet Explorer click here.

      MIB Name   Version 1   Version 2   Dependencies
    1. SNMPv2-SMI Download  |  Download  |  View Dependencies
    2. SNMPv2-TC Download  |  Download  |  View Dependencies
    3. IANAifType-MIB Download  |  Download  |  View Dependencies
    4. SNMPv2-CONF Not Required  |  Download  |  View Dependencies
    5. RFC1155-SMI   Non-Cisco MIB   |  Non-Cisco MIB   |  -
    6. RFC-1212   Non-Cisco MIB   |  Non-Cisco MIB   |  -
    7. SNMPv2-MIB Download  |  Download  |  View Dependencies
    8. RFC1213-MIB Not Required  |  Download  |  View Dependencies
    9. IF-MIB Download  |  Download  |  View Dependencies
    10. RFC1271-MIB Not Required  |  Download  |  View Dependencies
    11. BRIDGE-MIB Download  |  Download  |  View Dependencies
    12. TOKEN-RING-RMON-MIB Not Required  |  Download  |  View Dependencies
    13. RMON-MIB Download  |  Download  |  View Dependencies
    14. CISCO-SMI Download  |  Download  |  View Dependencies
    15. RMON2-MIB Download  |  Download  |  View Dependencies
    16. SNMP-FRAMEWORK-MIB Download  |  Download  |  View Dependencies
    17. P-BRIDGE-MIB   Non-Cisco MIB   |  Non-Cisco MIB   |  -
    18. CISCO-TC Download  |  Download  |  View Dependencies
    19. INET-ADDRESS-MIB Download  |  Download  |  View Dependencies
    20. Q-BRIDGE-MIB   Non-Cisco MIB   |  Non-Cisco MIB   |  -
    21. CISCO-FLOW-MONITOR-TC-MIB Download  |  Download  |  View Dependencies
    22. CISCO-REPORT-INTERVAL-TC-MIB   Non-Cisco MIB   |  Non-Cisco MIB   |  -
    23. SNMPv2-TC-v1   Non-Cisco MIB   |  Non-Cisco MIB   |  -
    24. CISCO-FLOW-MONITOR-MIB Download  |  Download  |  View Dependencies
    25. CISCO-RTP-METRICS-MIB Download  |  Download  | 

More Downloads

None

Extra Information

None

MIB Contents

This is the SMI version 2 of the MIB. Click here to see the SMI version 1
        
		
            
                
                    


-- *****************************************************************
-- CISCO-RTP-METRICS-MIB
-- Definitions of managed objects describing RTP flow metrics.
--   
-- October 2008, Patrick R. Gili
--   
-- Copyright (c) 2008-2009 by Cisco Systems Inc.
-- All rights reserved.
-- *****************************************************************

CISCO-RTP-METRICS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-IDENTITY,
    OBJECT-TYPE,
    Counter64,
    Gauge32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE,
    OBJECT-GROUP
        FROM SNMPv2-CONF
    TimeStamp
        FROM SNMPv2-TC
    ReportIntervalCount
        FROM CISCO-REPORT-INTERVAL-TC-MIB
    FlowMetricScale,
    FlowMetricPrecision,
    FlowMetricValue
        FROM CISCO-FLOW-MONITOR-TC-MIB
    cfmFlowMonitorId,
    cfmFlowId,
    cfmFlowMetricsIntNumber
        FROM CISCO-FLOW-MONITOR-MIB
    ciscoMgmt
        FROM CISCO-SMI;


ciscoRtpMetricsMIB MODULE-IDENTITY
    LAST-UPDATED    "200906170000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal:  170 W Tasman Drive
            San Jose, CA 95134

            Tel:  +1 800 553-NETS

            E-mail:  cs-snmp@cisco.com"
    DESCRIPTION        "This MIB module defines objects that describe the quality
        metrics of RTP streams, similar to those described by an RTCP
        Receiver Report packet [RFC3550].

        GLOSSARY
        ============

        Expected Packets - this value is formally defined as the
            extended last sequence number received less the initial
            sequence number received.

            An extended last sequence number is a 32-bit value, where
            the most significant 16-bit word indicates the number of
            sequence number cycles, and the least significant 16-bit
            word indicates the highest sequence number received.

        Flow Monitor - a hardware or software entity that classifies
            traffic flows, collects flow data, and periodically
            computes flow metrics.

        Flow Metric - a measurement that reflects the quality of a
            traffic flow.

        Inter-Arrival Jitter - an estimate of the statistical variance
            of the RTP data packet inter-arrival time.

            The inter-arrival jitter, J, is formally defined to be the
            mean deviation (smoothed absolute value) of the difference,
            D, in packet spacing at the flow monitor compared to the
            sender for a pair of packets.  This is equivalent to the
            difference in the relative transit time for two packets; the
            relative transit time is the difference between a packet's
            RTP timestamp and the device's clock at the time of arrival
            (measured in the same units):

                D(i,j) = (Rj - Ri) - (Sj - Si) = (Rj - Sj) - (Ri - Si)

            where Si is the RTP timestamp from packet i, and Ri is the
            time of arrival in RTP timestamp units for packet i.

            The inter-arrival jitter SHOULD be calculated continuously
            for each RTP data packet received from source SSRCn, using
            this equation to compute difference for each packet and the
            previous packet (in order of arrival, not necessarily in
            sequence).

                                |D(i-1,i)| - J(i-1)
                J(i) = J(i-1) + -------------------
                                         16

        Measurement Interval - the length of time over which a flow
            monitor collects data related to a traffic flow, after which
            the flow monitor computes flow metrics using the collected
            data.

        Loss Distance - the difference between the sequence numbers
            delimiting the start of two consecutive loss intervals.

            Consider the following sequence of RTP data packets:

                111111 111222    2233   33333 444  444 5
                123456x890123xxxx8901xxx56789x123xx678x0

                      ^      ^       ^       ^   ^    ^
                      |      |       |       |   |    |
                     LI1    LI2     LI3     LI4 LI5  LI6

              Loss Interval | Loss Distance
             ===============+===============
                     1      |
                     2      |      7
                     3      |      8
                     4      |      8
                     5      |      4
                     6      |      5

        Loss Fraction - the fraction of RTP data packets from source
            SSRCn lost during a measurement interval, expressed as a
            fixed-point number:

                      Li
                Fi = ----
                      Ei

            where Fi is the loss fraction for measurement interval i,
            Li is the lost packets during measurement interval i, and
            Ei is the expected packets during measurement interval i.

            Observe that the number of packets lost includes packets
            that are late or duplicates, and hence this number can can
            have a theoretical theoretical value between negative
            infinity and one.

            The cumulative loss fraction is the fraction of RTP data
            packets from source SSRCn lost over the duration 
            monitoring the flow:

                       n
                      sum [Li]
                      i=1
                Fn = ----------
                       n
                      sum [Ei]
                      i=1

            where Fn is the cumulative loss fraction over n measurement
            intervals.

        Loss Interval - an interval in which consecutive packet losses
            were experienced.

            Consider the following sequence of RTP data packets:

                111111 111222    2233   33333 444  444 5
                123456x890123xxxx8901xxx56789x123xx678x0

                      ^      ^       ^       ^   ^    ^
                      |      |       |       |   |    |
                     LI1    LI2     LI3     LI4 LI5  LI6

            LI1 through LI6 indicate the start of loss intervals
            observed in this sequence.

        Loss Interval Duration - the number of packets lost in a loss
            interval.

            Consider the following sequence of RTP data packets:

                111111 111222    2233   33333 444  444 5
                123456x890123xxxx8901xxx56789x123xx678x0

                      ^      ^       ^       ^   ^    ^
                      |      |       |       |   |    |
                     LI1    LI2     LI3     LI4 LI5  LI6

             Loss Interval | Duration
            ===============+==========
                    1      |    1
                    2      |    4
                    3      |    3
                    4      |    1
                    5      |    2
                    6      |    1

        Lost Packets - this value is formally defined as the number of
            packets expected less the number of packets actually
            received, where the number of packets received includes
            those which are late or duplicates.

        SSRCn - the SSRC identifier of the source.

        Traffic Flow - a unidirectional stream of packets conforming to
            a classifier.  For example, packets having a particular 
            source IP address, destination IP address, protocol type,
            source port number, and destination port number.

        Transit Time - the latency from the insertion into the network
            to the flow monitor.  This value can be computed by taking
            the difference between a packet's RTP timestamp and the
            device's clock at the time of arrival (measured in the same
            units).

        REFERENCES
        ==============

        [RFC3550]   H. Schlzrinne, S. Casner, R. Frederick, V. Jacobson,
                    'RTP: A Transport Protocol for Real-Time
                    Applications', RFC-3550, July 2003.
"
    REVISION        "200906170000Z"
    DESCRIPTION        "The initial version of the MIB module.
"
    ::= { ciscoMgmt 703 }


-- **********************************************************************
-- * Top-Level Trees                                                    *
-- **********************************************************************

ciscoRtpMetricsMIBNotifs  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIB 0 }

ciscoRtpMetricsMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIB 1 }

ciscoRtpMetricsMIBConform  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIB 2 }

ciscoRtpMetricsMIBIds  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIB 3 }

-- **********************************************************************
-- * Objects                                                            *
-- **********************************************************************

cfmRtpMetrics  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIBObjects 1 }


cfmRtpMetricsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CfmRtpMetricsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION        "This table contains aggregate data maintained by a flow
        monitor for traffic flows for which it is computing RTP
        metrics.

        This table has an sparse dependent relationship on the
        cfmFlowMetricsTable (defined by the CISCO-FLOW-MONITOR-MIB),
        containing a row for each row in the cfmFlowMetricsTable having
        a corresponding instance of cfmFlowMetricsCollected with the
        'rtp' bit set to one.
"
    ::= { cfmRtpMetrics 1 }

cfmRtpMetricsEntry OBJECT-TYPE
    SYNTAX          CfmRtpMetricsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION        "An entry describes cumulative and aggregate RTP metrics for a
        single traffic flow.

        The devices creates a row in the cfmRtpMetricsTable when a flow
        monitor starts monitoring a traffic flow and has been configured
        to compute RTP metrics for the same traffic flow. Likewise, the
        device destroys a row in the cfmRtpMetricsTable when the
        corresponding flow monitor has ceased monitoring the traffic
        flow (e.g., when a traffic flow has timed out).
"
    INDEX           {
                        cfmFlowMonitorId,
                        cfmFlowId
                    } 
    ::= { cfmRtpMetricsTable 1 }

CfmRtpMetricsEntry ::= SEQUENCE {
        cfmRtpMetricsValid           BITS,
        cfmRtpMetricsExpectedPkts    Counter64,
        cfmRtpMetricsLostPkts        Counter64,
        cfmRtpMetricsFracScale       FlowMetricScale,
        cfmRtpMetricsFracPrecision   FlowMetricPrecision,
        cfmRtpMetricsFrac            FlowMetricValue,
        cfmRtpMetricsLIs             Counter64,
        cfmRtpMetricsAvgLDScale      FlowMetricScale,
        cfmRtpMetricsAvgLDPrecision  FlowMetricPrecision,
        cfmRtpMetricsAvgLD           FlowMetricValue,
        cfmRtpMetricsAvgLossDistance Gauge32,
        cfmRtpMetricsJitterScale     FlowMetricScale,
        cfmRtpMetricsJitterPrecision FlowMetricPrecision,
        cfmRtpMetricsJitter          FlowMetricValue
}

cfmRtpMetricsValid OBJECT-TYPE
    SYNTAX          BITS {
                        expectedPkts(0),
                        lostPkts(1),
                        lossFraction(2),
                        lossIntervals(3),
                        avgLossDuration(4),
                        avgLossDistance(5),
                        jitter(6)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates which metrics are valid for the traffic
        flow:

            'expectedPkts'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsExpectedPkts is valid.

            'lostPkts'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsLostPkts is valid.

            'lossFraction'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsFracScale,
                cfmRtpMetricsFracPrecision, and cfmRtpMetricsFrac are
                valid.

            'lossIntervals'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsLIs is valid.

            'avgLossIntervalDuration'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsAvgLDScale,
                cfmRtpMetricsAvgLDPrecision, and cfmRtpMetricsAvgLD are
                valid.

            'avgLossDistance'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsAvgLossDistance is valid.

            'jitter'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsJitterScale,
                cfmRtpMetricsJitterPrecision, and cfmRtpMetricsJitter
                are valid.
" 
    ::= { cfmRtpMetricsEntry 1 }

cfmRtpMetricsExpectedPkts OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the number of RTP packets expected for
        the traffic flow.
" 
    ::= { cfmRtpMetricsEntry 2 }

cfmRtpMetricsLostPkts OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the number of RTP packets lost for the
        traffic flow.
" 
    ::= { cfmRtpMetricsEntry 3 }

cfmRtpMetricsFracScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsFrac.
" 
    ::= { cfmRtpMetricsEntry 4 }

cfmRtpMetricsFracPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpmetricsFrac.
" 
    ::= { cfmRtpMetricsEntry 5 }

cfmRtpMetricsFrac OBJECT-TYPE
    SYNTAX          FlowMetricValue
    MAX-ACCESS      read-only
    STATUS          current
   DESCRIPTION        "This object indicates the loss fraction for traffic flow.
"
    ::= { cfmRtpMetricsEntry 6 }

cfmRtpMetricsLIs OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the number of loss intervals for the
        traffic flow.
" 
    ::= { cfmRtpMetricsEntry 7 }

cfmRtpMetricsAvgLDScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsAvgLD.
" 
    ::= { cfmRtpMetricsEntry 8 }

cfmRtpMetricsAvgLDPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpMetricsAvgLD.
" 
    ::= { cfmRtpMetricsEntry 9 }

cfmRtpMetricsAvgLD OBJECT-TYPE
    SYNTAX          FlowMetricValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the average loss duration for the
        traffic flow.
" 
    ::= { cfmRtpMetricsEntry 10 }

cfmRtpMetricsAvgLossDistance OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the average loss distance for the
        traffic flow.
" 
    ::= { cfmRtpMetricsEntry 11 }

cfmRtpMetricsJitterScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsJitter.
" 
    ::= { cfmRtpMetricsEntry 12 }

cfmRtpMetricsJitterPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpMetricsJitter.
" 
    ::= { cfmRtpMetricsEntry 13 }

cfmRtpMetricsJitter OBJECT-TYPE
    SYNTAX          FlowMetricValue
    UNITS           "seconds"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the inter-arrival jitter for the traffic
        flow.
" 
    ::= { cfmRtpMetricsEntry 14 }
 


cfmRtpMetricsTableChanged OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the value of sysUpTime the last time the
        device created/destroyed a row in the cfmRtpMetricsTable.
" 
    ::= { cfmRtpMetrics 2 }

cfmRtpMetricsIntTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CfmRtpMetricsIntEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION        "This table contains historic RTP metrics for the traffic flows
        monitored by each of the flow monitors supported by the device.

        This table has an sparse dependent relationship on the
        cfmFlowMetricsIntTable (defined by the CISCO-FLOW-MONITOR-MIB),
        containing a row for each row in the cfmFlowMetricsIntTable
        having a corresponding instance of cfmFlowMetricsCollected with
        the 'rtp' bit set to one.
"
    ::= { cfmRtpMetrics 3 }

cfmRtpMetricsIntEntry OBJECT-TYPE
    SYNTAX          CfmRtpMetricsIntEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION        "An entry describes RTP metrics collected for a previous
        measurement interval for a corresponding traffic flow.
"
    INDEX           {
                        cfmFlowMonitorId,
                        cfmFlowId,
                        cfmFlowMetricsIntNumber
                    } 
    ::= { cfmRtpMetricsIntTable 1 }

CfmRtpMetricsIntEntry ::= SEQUENCE {
        cfmRtpMetricsIntValid            BITS,
        cfmRtpMetricsIntExpectedPkts     ReportIntervalCount,
        cfmRtpMetricsIntLostPkts         ReportIntervalCount,
        cfmRtpMetricsIntFracScale        FlowMetricScale,
        cfmRtpMetricsIntFracPrecision    FlowMetricPrecision,
        cfmRtpMetricsIntFrac             FlowMetricValue,
        cfmRtpMetricsIntLIs              ReportIntervalCount,
        cfmRtpMetricsIntAvgLDScale       FlowMetricScale,
        cfmRtpMetricsIntAvgLDPrecision   FlowMetricPrecision,
        cfmRtpMetricsIntAvgLD            FlowMetricValue,
        cfmRtpMetricsIntAvgLossDistance  ReportIntervalCount,
        cfmRtpMetricsIntJitterScale      FlowMetricScale,
        cfmRtpMetricsIntJitterPrecision  FlowMetricPrecision,
        cfmRtpMetricsIntJitter           FlowMetricValue,
        cfmRtpMetricsIntTransitScale     FlowMetricScale,
        cfmRtpMetricsIntTransitPrecision FlowMetricPrecision,
        cfmRtpMetricsIntTransit          FlowMetricValue
}

cfmRtpMetricsIntValid OBJECT-TYPE
    SYNTAX          BITS {
                        expectedPkts(0),
                        lostPkts(1),
                        lossFraction(2),
                        lossIntervals(3),
                        avgLossIntervalDuration(4),
                        avgLossDistance(5),
                        maxJitter(6),
                        maxMinTransit(7)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates which metrics are valid for the
        measurement interval:

            'expectedPkts'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsIntExpectedPkts is valid.

            'lostPkts'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsIntLostPkts is valid.

            'lossFraction'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsIntFracScale,
                cfmRtpMetricsIntFracPrecision, and cfmRtpMetricsIntFrac
                are valid.

            'lossIntervals'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsIntLIs is valid.

            'avgLossDuration'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsIntAvgLDScale,
                cfmRtpMetricsIntAvgLDPrecision, and
                cfmRtpMetricsIntAvgLD are valid.

            'avgLossDistance'
                If this bit is set to '1', then the corresponding
                instance of cfmRtpMetricsIntAvgLossDistance is valid.

            'maxJitter'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsIntJitterScale,
                cfmRtpMetricsIntJitterPrecision, and
                cfmRtpMetricsIntJitter are valid.

            'maxMinTransit'
                If this bit is set to '1', then the corresponding
                instances of cfmRtpMetricsIntTransitScale,
                cfmRtpMetricsIntTransitPrecision, and
                cfmRtpMetricsIntTransit are valid.
" 
    ::= { cfmRtpMetricsIntEntry 1 }

cfmRtpMetricsIntExpectedPkts OBJECT-TYPE
    SYNTAX          ReportIntervalCount
    UNITS           "packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the number of RTP packets expected for
        the traffic flow during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 2 }

cfmRtpMetricsIntLostPkts OBJECT-TYPE
    SYNTAX          ReportIntervalCount
    UNITS           "packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the number of RTP packets lost for the
        traffic flow during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 3 }

cfmRtpMetricsIntFracScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsIntFrac.
" 
    ::= { cfmRtpMetricsIntEntry 4 }

cfmRtpMetricsIntFracPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpmetricsIntFrac.
" 
    ::= { cfmRtpMetricsIntEntry 5 }

cfmRtpMetricsIntFrac OBJECT-TYPE
    SYNTAX          FlowMetricValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the loss fraction for traffic flow
        during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 6 }

cfmRtpMetricsIntLIs OBJECT-TYPE
    SYNTAX          ReportIntervalCount
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the number of loss intervals for the
        traffic flow during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 7 }

cfmRtpMetricsIntAvgLDScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsIntAvgLD.
" 
    ::= { cfmRtpMetricsIntEntry 8 }

cfmRtpMetricsIntAvgLDPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpMetricsIntAvgLD.
" 
    ::= { cfmRtpMetricsIntEntry 9 }

cfmRtpMetricsIntAvgLD OBJECT-TYPE
    SYNTAX          FlowMetricValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the average loss duration for the
        traffic flow during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 10 }

cfmRtpMetricsIntAvgLossDistance OBJECT-TYPE
    SYNTAX          ReportIntervalCount
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the average loss distance for the
        traffic flow during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 11 }

cfmRtpMetricsIntJitterScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsIntJitter.
" 
    ::= { cfmRtpMetricsIntEntry 12 }

cfmRtpMetricsIntJitterPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpMetricsIntJitter.
" 
    ::= { cfmRtpMetricsIntEntry 13 }

cfmRtpMetricsIntJitter OBJECT-TYPE
    SYNTAX          FlowMetricValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the maximum inter-arrival jitter for the
        traffic flow during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 14 }

cfmRtpMetricsIntTransitScale OBJECT-TYPE
    SYNTAX          FlowMetricScale
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the scaling factor for the corresponding
        instance of cfmRtpMetricsIntTransit.
" 
    ::= { cfmRtpMetricsIntEntry 15 }

cfmRtpMetricsIntTransitPrecision OBJECT-TYPE
    SYNTAX          FlowMetricPrecision
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the precision for the corresponding
        instance of cfmRtpMetricsIntTransit.
" 
    ::= { cfmRtpMetricsIntEntry 16 }

cfmRtpMetricsIntTransit OBJECT-TYPE
    SYNTAX          FlowMetricValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION        "This object indicates the max-min transit time for the traffic
        flow during the measurement interval.  The max-min transit is
        the difference between the maximum and minimum transit times
        observed for RTP data packets during the measurement interval.
" 
    ::= { cfmRtpMetricsIntEntry 17 }
 

-- **********************************************************************
-- * Object Identifiers                                                 *
-- **********************************************************************

cfmRtpMonitoredElements  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIBIds 1 }


cfmeRtpSsrcMismatch OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the condition that arises when a flow monitor
        detects a RTP SSRC mismatch for a traffic flow during the last
        measurement interval.
"
    ::= { cfmRtpMonitoredElements 1 }


cfmeRtpCumulativeLostPkts OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the cumulative number of lost RTP data packets for a
        traffic flow (cfmRtpMetricsLostPkts).
"
    ::= { cfmRtpMonitoredElements 2 }


cfmeRtpCumulativeLossFraction OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the cumulative RTP loss fraction for a traffic flow
        (cfmRtpMetricsFrac).
"
    ::= { cfmRtpMonitoredElements 3 }


cfmeRtpCumulativeLossIntervals OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the cumulative number of RTP loss intervals for a
        traffic flow (cfmRtpMetricsLIs).
"
    ::= { cfmRtpMonitoredElements 4 }


cfmeRtpCumulativeAvgLossDuration OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the average duration of a RTP loss interval for a
        traffic flow (cfmRtpMetricsAvgLD).
"
    ::= { cfmRtpMonitoredElements 5 }


cfmeRtpCumulativeAvgLossDistance OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the average RTP loss distance for a traffic flow
        (cfmRtpMetricsAvgLossDistance).
"
    ::= { cfmRtpMonitoredElements 6 }


cfmeRtpCumulativeJitter OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the average inter-arrival jitter of RTP data
        packets for a traffic flow (cfmRtpMetricsJitter).
"
    ::= { cfmRtpMonitoredElements 7 }


cfmeRtpLostPkts OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the number of lost RTP data packets for a traffic
        flow during the last measurement interval
        (cfmRtpMetricsIntLostPkts).
"
    ::= { cfmRtpMonitoredElements 8 }


cfmeRtpLossFraction OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the RTP loss fraction for a traffic flow during the
        last measurement interval (cfmRtpMetricsIntFrac).
"
    ::= { cfmRtpMonitoredElements 9 }


cfmeRtpLossIntervals OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the number of RTP loss intervals for a traffic flow
        during the last measurement interval (cfmRtpMetricsIntLIs).
"
    ::= { cfmRtpMonitoredElements 10 }


cfmeRtpAvgLossDuration OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the average duration of a RTP loss interval for
        a traffic flow during the last measurement interval
        (cfmRtpMetricsIntAvgLD).
"
    ::= { cfmRtpMonitoredElements 11 }


cfmeRtpAvgLossDistance OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the average RTP loss distance for a traffic flow
        during the last measurement interval
        (cfmRtpMetricsIntAvgLossDistance).
"
    ::= { cfmRtpMonitoredElements 12 }


cfmeRtpMaxJitter OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the maximum inter-arrival jitter of RTP data packets
        for a traffic flow during the last measurement interval
        (cfmRtpMetricsIntJitter).
"
    ::= { cfmRtpMonitoredElements 13 }


cfmeRtpMaxMinTransit OBJECT-IDENTITY
    STATUS          current
    DESCRIPTION        "This object identifier represents the monitored element
        describing the max-min transit time of the RTP data packets for
        a traffic flow during the last measurement interval
        (cfmRtpMetricsIntTransit).
"
    ::= { cfmRtpMonitoredElements 14 }

-- **********************************************************************
-- * Conformance                                                        *
-- **********************************************************************

ciscoRtpMetricsMIBCompliances  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIBConform 1 }

ciscoRtpMetricsMIBGroups  OBJECT IDENTIFIER
    ::= { ciscoRtpMetricsMIBConform 2 }


ciscoRtpMetricsCompliance01 MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION        "This compliance statement specifies the minimal requirements an
        implementation must meet in order to claim full compliance with
        the definition of the CISCO-RTP-METRICS-MIB.
"
    MODULE          -- this module
    MANDATORY-GROUPS { cfmRtpMetricsGroup }
    ::= { ciscoRtpMetricsMIBCompliances 1 }

-- **********************************************************************
-- * Units of Conformance                                               *
-- **********************************************************************

cfmRtpMetricsGroup OBJECT-GROUP
    OBJECTS         {
                        cfmRtpMetricsValid,
                        cfmRtpMetricsExpectedPkts,
                        cfmRtpMetricsLostPkts,
                        cfmRtpMetricsFracScale,
                        cfmRtpMetricsFracPrecision,
                        cfmRtpMetricsFrac,
                        cfmRtpMetricsLIs,
                        cfmRtpMetricsAvgLDScale,
                        cfmRtpMetricsAvgLDPrecision,
                        cfmRtpMetricsAvgLD,
                        cfmRtpMetricsAvgLossDistance,
                        cfmRtpMetricsJitterScale,
                        cfmRtpMetricsJitterPrecision,
                        cfmRtpMetricsJitter,
                        cfmRtpMetricsTableChanged,
                        cfmRtpMetricsIntValid,
                        cfmRtpMetricsIntExpectedPkts,
                        cfmRtpMetricsIntLostPkts,
                        cfmRtpMetricsIntFracScale,
                        cfmRtpMetricsIntFracPrecision,
                        cfmRtpMetricsIntFrac,
                        cfmRtpMetricsIntLIs,
                        cfmRtpMetricsIntAvgLDScale,
                        cfmRtpMetricsIntAvgLDPrecision,
                        cfmRtpMetricsIntAvgLD,
                        cfmRtpMetricsIntAvgLossDistance,
                        cfmRtpMetricsIntJitterScale,
                        cfmRtpMetricsIntJitterPrecision,
                        cfmRtpMetricsIntJitter,
                        cfmRtpMetricsIntTransitScale,
                        cfmRtpMetricsIntTransitPrecision,
                        cfmRtpMetricsIntTransit
                    }
    STATUS          current
    DESCRIPTION        "This group contains objects that describe RTP metrics.
"
    ::= { ciscoRtpMetricsMIBGroups 1 }

END











                
                
            
			
        
   