This document describes one of the reasons why the Cisco ONS 15305 can generate an inventory failure error message, and provides the solution.
www.cisco.com/en/US/products/hw/optical/ps2001/products_tech_note09186a00802bdc90.shtml
02 Feb 2005
...minutes before removing the module, to avoid hazardous discharge Step 3 Remove the AC 230V module if necessary. This section describes installation procedures that are common...module type. For details on each Service modules see...of only two modules per ONS 15305 chassis. This is only related...chassis. All modules store inventory data in non-volatile memory...
www.cisco.com/en/US/products/hw/optical/ps2001/products_installation_and_configuration_guide_chapter09186a00808bdb49.html
14 Sep 2007
...minutes before removing the module, to avoid hazardous discharge Step 3 Remove the AC 230V module if necessary. This chapter describes installation procedures that are common...module type. For details on each Service modules see...of only two modules per ONS 15305 chassis. This is only related...chassis. All modules store inventory data in non-volatile memory...
www.cisco.com/en/US/products/hw/optical/ps2001/products_installation_and_configuration_guide_chapter09186a00808bdc1b.html
14 Sep 2007
... 3. Installing the ONS 15305 AC 230V Power 4. Installing External Ground to the ONS 15305 5. Installing Service Modules 6. Installing the Ground...assembly is allocated for installation in a 19-in. (482.6-mm...separately. Step 1 Depending on back access issues, choose...
www.cisco.com/en/US/products/hw/optical/ps2001/prod_quick_installation_guide09186a00808bda6f.html
14 Sep 2007
...equipment, for example power module failure, battery condition, open...output connector is placed on the fan unit front cover...2-7 Location of Alarm and Fan Module, FAN-ALARM The main feature...end. This cable connects the ONS 15305 to the internal 48V power-rails...The module contains a 75 W AC/DC converter that converts the input voltage from 230V to +5.25V. The module...
www.cisco.com/en/US/products/hw/optical/ps2001/products_installation_and_configuration_guide_chapter09186a00808bdb4d.html
14 Sep 2007
...minutes before removing the module, to avoid hazardous discharge Step 3 Remove the AC 230V module if necessary. It is vital that the ONS 15305 cabinet is properly grounded...ONS15305 brackets are mounted on unpainted rack area... This section describes installation procedures that are common...chassis. All modules store inventory data in non-volatile memory...
www.cisco.com/en/US/products/hw/optical/ps2001/prod_quick_installation_guide09186a00808bda57.html
14 Sep 2007
...equipment, for example power module failure, battery condition, open...output connector is placed on the fan unit front cover as...2-7 Location of Alarm and Fan Module, FAN-ALARM The main feature...end. This cable connects the ONS 15305 to the internal 48V power-rails...It is not recommended that AC power module and DC power module...describes the Power Module AC 230V shown in Figure 2-9. ...
www.cisco.com/en/US/products/hw/optical/ps2001/products_installation_and_configuration_guide_chapter09186a00808bdb53.html
14 Sep 2007
...15310 and ML Card on ONS 15454 10/Apr/2006 Inventory Failure on ONS 15305 - AC 230V Module Installation 02/Feb/2005...
www.cisco.com/en/US/products/hw/optical/ps2001/prod_tech_notes_list.html
25 Apr 2005
...provided to indicate an ONS 15305 failure condition. These LEDs are placed on the System Controller Unit...cover and the front of the ONS 15305, as shown in Figure...port. 2.4 Service Modules 2.4.1 Introduction...2-9 Cisco ONS 15305 Installation and Operations Guide OL-4284-02...Memory All modules store inventory data in non-volatile memory...
www.cisco.com/en/US/docs/optical/15000r3_0/15305/install/guide/305r1.pdf
1673KB
...chassis. All modules store inventory data in non-volatile memory. The inventory data is accessible from...management system. All modules contain a LED that indicates...deactivated. 4-10 Cisco ONS 15305 Installation and Operations Guide ...one status LED indicator on the front of the module...Figure 4-4 LED for Module Failure Located in Lower Left Corner...
www.cisco.com/en/US/docs/optical/15000r3_0/15305/install/guide/305R1C4.pdf
436KB